ubuntu – Minicom什么都没显示

~$dmesg | grep tty
[    0.000000] console [tty0] enabled
[   15.905810] usb 3-3: pl2303 converter now attached to ttyUSB0
[ 3910.549952] pl2303 ttyUSB0: pl2303 converter now disconnected from ttyUSB0
[ 3929.763287] usb 3-3: pl2303 converter now attached to ttyUSB0


~$lsusb
Bus 003 Device 002: ID 067b:2303 Prolific Technology, Inc. PL2303 Serial Port

Minicom configuration
| A -    Serial Device      : /dev/ttyUSB0                              |
| B - Lockfile Location     : /var/lock                                 |
| C -   Callin Program      :                                           |
| D -  Callout Program      :                                           |
| E -    Bps/Par/Bits       : 115200 8N1                                |
| F - Hardware Flow Control : No                                        |
| G - Software Flow Control : No                                        |

然后它给出了没有其他事情发生

Welcome to minicom 2.4

OPTIONS: I18n                                                                
Compiled on Jan 25 2010, 07:02:36.                                           
Port /dev/ttyUSB0                                                            

Press CTRL-A Z for help on special keys                                      

我google了很多,跟着各种各样的tutos.但问题仍然存在.我想知道董事会本身是否有问题?

请帮忙,谢谢

编辑1:很抱歉没有澄清问题.事实上,我连接到一个pandabandard OMAP4430.

编辑2:嗯,实际上我得到了它的工作.问题是uboot映像坏了,所以我使用JTAG重新刷新一个新映像.很抱歉没有澄清问题并使这个问题很麻烦.

最佳答案 关闭minicom中的硬件流控制后,您必须退出然后返回才能生效.

你需要检查你的波特率,ctrl-a p然后下一个或更低.

你发送到电脑的是什么?你可以在串口上的套接字2和3之间使用回形针来回路.规则是女性总是正确的,当看到d-shell连接器时,如果插座有较宽的部分,那么右上方的针脚是针脚1,两个位于顶行的左侧,依此类推.如果针脚而不是插座,那么左上角是针脚1,这些天连接器通常在塑料成型中具有凸起的数字.如果您在minicom窗口上键入的内容应该缩短,应该循环回来并在屏幕上看到.

有没有其他/ dev / tty *设备,你没有考虑,也许你有两个/ dev / ttyUSBx设备,你正在关注错误的设备.

点赞